Be constructed of those materials listed in Section P2905.5 or materials tested, rated and approved for such use in accordance with ASME A112.4.1. Not have a threaded connection at the end of the piping. Not terminate more than 6 inches (152 mm) above the floor or waste receptor. Discharge to a termination point that is readily observable by the building occupants.

water heater overflow pipe requirements

Discharge in a manner that does not cause personal injury or structural damage. Discharge to the floor, to the pan serving the water heater or storage tank, to a waste receptor or to the outdoors. Serve a single relief device and shall not connect to piping serving any other relief device or equipment.

#WATER HEATER OVERFLOW PIPE REQUIREMENTS FULL SIZE#

Not be smaller than the diameter of the outlet of the valve served and shall discharge full size to the air gap. Discharge through an air gap located in the same room as the water heater. Not be directly connected to the drainage system. The discharge piping serving a pressure-relief valve, temperature-relief valve or combination valve shall: P2803.6.1 Requirements for discharge pipe. These are the requirements: (bold and underlining are mine)

#WATER HEATER OVERFLOW PIPE REQUIREMENTS CODE#

The T&P relief valve discharge piping was required to meet the code in effect at the time the new water and new T&P were installed - i.e., the discharge piping had to be rerouted to terminate in the same room or space as the water heater was located. This requirement goes back to maybe 2003 or 2006, I'd have to look it up to verify when it changed. In 2012, the T&P discharge piping was (and still is) required to terminate in the same room or space where the water heater is located. Structural Question - Interior Wall Touching Garage Floor Gradeįinding dates (1981) regarding these requirements were unsuccessful.In 1981, the T&P discharge piping was required to extend to, and terminate, outside.Questionable part is with this termination location does it discharge as to not cause personal injury or structural damage?įinding dates (1981) regarding these requirements were unsuccessful. It is readily observable, 6 inches above floor. It could easily be routed to the exterior. appears to be the original configuration with newer water hater installed in 2012. There were no obvious indications that the garage was converted from a carport which is very common here in Southern AZ. Can you tell me if that was an industry standard when this house was built or are you recommending this house be brought up to current code? We can assume the recommendation is the industry standard. Q: On the TP relief value you recommend this be re-routed to the outside per industry standards. Question from client(Hunch that it is actually coming from sellers agent) based on similar tactics from this particular agent in the past. Need some clarification on this common issue and weather it should be a recommended upgrade, further review or repair.